FixVault

Without Tachometer

Remove instrument cluster. Connect ohmmeter leads to "FU" and "E" terminals of printed circuit. Resistance should be about 55 ohms. See Fig 1 .

Fig 1: Checking Fuel Gauge (W/O Tachometer)