FixVault

Right Mirror Does Not Operate In Up/Down Or Left/Right Mode

  1. Disconnect right power mirror connector. Connect test light between power mirror connector terminal "A" (Light Blue wire) and ground. With right mirror selected, move power mirror switch to down position. If test light glows, go to next step. If test light does not glow, check for open in Light Blue wire between power mirror switch and right power mirror. If circuit is okay, replace power mirror switch.
  2. Connect test light between right power mirror connector terminals "A" (Light Blue wire) and "C" (Brown/White wire). Move power mirror switch to up, then down positions. If test light glows in both positions, go to next step. If test light does not glow in both positions, check for open in Brown/White wire between power mirror switch and right power mirror. If circuit is okay, replace power mirror switch.
  3. Connect test light between right power mirror connector terminals "A" (Light Blue wire) and "B" (Red/White wire). Move power mirror switch to left, then right positions. If test light glows in both positions, replace right power mirror drive unit. If test light does not glow in both positions, check for open in Red/White wire between power mirror switch and right power mirror. If circuit is okay, replace power mirror switch.