Fresh/Recirculated Air Control Cable

Disconnect fresh/recirculated air control cable from clip and door at blower case. Set fresh/recirculated air lever to recirculated air position. At blower case, push door lever fully rearward (counterclockwise) and attach cable with cable clip. See Fig 1. Check fresh/recirculated air lever for smooth operation and ensure that it stops in correct spots.

Fig 1: Identifying Heater Cables
G98D03123Courtesy of GENERAL MOTORS CORP.