Installation Procedure
Important: Do not use RTV or any other type of sealant on the EBCM gasket or mating surfaces.
- Install EBCM (2) onto BPMV (5).
Important: Do not reuse the old mounting bolts. Always install new bolts with the new BPMV.
- Install the 4 EBCM bolts (1). Tighten the 4 bolts to 5 N.m (39 lb in) in an X-pattern.
- Connect the 2-way ABS pump motor connector to the EBCM.
- Install the BPMV (5) to the BPMV mounting bracket (3) with the 2 bolts (4).
- Slide the EHCU (1) back onto the frame bracket (2).
Important: The brake pipes are held in the proper place by a frame mounted plastic bracket. Make sure that the brake pipes stay in the correct place for proper reassembly.
- Install the 5 brake pipes to the EHCU (1). Tighten the brake pipe fittings to 30 N.m (22 lb ft). I
- Connect the 2 electrical harness connectors to the EBCM (1).
- Secure the module (1) to the frame bracket (3) and fuel pipe shield (2) with the 2 nuts (4).
- Bleed the brake system. Refer to ABS Automated Bleed Procedure .
- Return to Diagnostic System Check - ABS .