FixVault

Installation Procedure

  1. Install the heated oxygen sensor (HO2S).
  2. Install a new exhaust manifold pipe gasket to the exhaust manifold pipe studs.
  3. Install and support the three way catalytic converter.
  4. Install the catalytic converter bolts.
  5. Install the exhaust manifold pipe stud nuts.
    • Tighten the exhaust manifold pipe stud nuts to 32 N.m (24 ft lbs).
    • Tighten the catalytic converter bolts to 45 N.m (33 ft lbs).
  6. Connect the heated oxygen sensor (HO2S) electrical connector.
  7. Lower the vehicle.
  8. Inspect the exhaust system for leaks.