FixVault

Assembly Procedure

  1. Install the flow control spring (5), if removed from the pump housing (1).
  2. Lubricate the new O-ring seal (3) with power steering fluid.
    Fig 1: Power Steering Pump Flow Control Valve Assembly
    GM580317Courtesy of GENERAL MOTORS CORP.
  3. Install the O-ring seal (3) onto the connector and fitting assembly (2).
  4. Install the control valve assembly (4).
  5. NOTE: Refer to Fastener Notice in Cautions and Notices.
  6. Install the connector and fitting assembly (2).

    Tighten:  Tighten the connector and fitting assembly to 75 N.m (55 lb ft).