Scan Tool Output Controls
Instrument Panel Cluster Scan Tool Output Controls
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| Coolant Gauge Sweep Test | IPC Gauges | The IPC drives the coolant gage at or above 125° C (260° F) when you select Up. The IPC drives the coolant gage at or below 60° C (140° F) when you select Down. |
| Fuel Gauge Sweep Test | IPC Gauges | The IPC drives the fuel gage at or above full when you select Up. The IPC drives the fuel gage at or below empty when you select Down. |
| Oil Gauge Sweep Test | IPC Gauges | The IPC drives the engine oil pressure gage at or above H when you select Up. The IPC drives the engine oil pressure gage at or below L when you select Down. |
| Speed Gauge Sweep Test | IPC Gauges | The IPC drives the speedometer at or above 200 km/h (120 MPH) (base) or 220 km/h (140 mph) (uplevel) when you select Up. The IPC drives the speedometer at or below 0 km/h (0 mph) when you select Down. |
| Tach Gauge Sweep Test | IPC Gauges | The IPC drives the tachometer at or above 7000 RPM when you select Up. The IPC drives the tachometer at or below 0 RPM when you select Down. |
| Volts Gauge Sweep Test | IPC Gauges | The IPC drives the volt gage at or above 18 volts when you select Up. The IPC drives the tachometer at or below 8 volts when you select Down. |
| Lamp Test | - | The IPC illuminates the following indicators when you select On:
The indicators illuminate until commanded Off. |
| 1st | PRNDL Display | The IPC illuminates the 1st gear position (1) on the IPC when you select On. The 1st gear position illuminates until commanded Off. |
| 2nd | PRNDL Display | The IPC illuminates the 2nd gear position (2) on the IPC when you select On. The 2nd gear position illuminates until commanded Off. |
| 3rd | PRNDL Display | The IPC illuminates the 3rd gear position (3) on the IPC when you select On. The 3rd gear position illuminates until commanded Off. |
| Drive | PRNDL Display | The IPC illuminates the drive position (D) on the IPC when you select On. The drive position illuminates until commanded Off. |
| Neutral | PRNDL Display | The IPC illuminates the neutral position (N) on the IPC when you select On. The neutral position illuminates until commanded Off. |
| Park | PRNDL Display | The IPC illuminates the park position (P) on the IPC when you select On. The park position illuminates until commanded Off. |
| Reverse | PRNDL Display | The IPC illuminates the reverse position (R) on the IPC when you select On. The reverse position illuminates until commanded Off. |
Powertrain Control Module Scan Tool Output Controls
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| Oil Life Reset | Engine Output Controls | The PCM resets the oil life to the value selected. |
| MIL | Engine Output Controls | The PCM commands the IPC to turn this lamp on and off. |