FixVault

Removal Procedure

  1. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
  2. Fig 1: View Of Daytime Running Lamp Module
    GM318092Courtesy of GENERAL MOTORS CORP.
  3. Remove the instrument panel insulator. Refer to Closeout/Insulator Panel Replacement - Left in Instrument Panel, Gages and Console.
  4. Fig 2: View Of Daytime Running Lamp Module & Bracket
    GM318094Courtesy of GENERAL MOTORS CORP.
  5. Slide the daytime running lamp module from the bracket.
  6. Disconnect the electrical connectors.