    Fig 1: Identifying ABS Wiring Harness Connector And ECBM
    GM1677244Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice .
  1. Install the 6 brake pipe fitting nuts.

    Tighten:  Tighten the nuts to 16 N.m (12 lb ft)  .

  2. Install the brake modulator assembly and secure with the mounting bracket bolts (2).

    Tighten:  Tighten the bolts to 22 N.m (16 lb ft)  .

  3. Connect the ABS wiring harness (2).
  4. Inspect the fluid level of the brake master cylinder. Add new brake fluid as required.
  5. Bleed the brake system. Refer to Hydraulic Brake System Bleeding .
  6. Test the brake system for leaks.
  7. Install the cooling surge tank. Refer to Surge Tank Replacement (2.0L) or Surge Tank Replacement (2.5L) .
  8. Connect the negative battery cable.