FixVault

Circuit/System Testing

  1. Ignition ON, loosen the fuel fill cap. Verify the FTP sensor parameter is 0 mmHg (0 inches H20).
    • If not at the specified value, replace the FTP sensor.
  2. Disconnect the purge line from the EVAP purge solenoid valve and connect a J 23738-A hand vacuum pump.
  3. Verify that the solenoid can hold 10 inches of vacuum for 30 seconds.
    • If the vacuum decreases, replace the EVAP purge solenoid valve.