FixVault

Circuit/System Testing

  1. Ignition ON, loosen the fuel fill cap. Verify the scan tool FTP sensor parameter is near 0 mmHg (0 in H2O).
    IMPORTANT: Refer to the J 41413-200  operation manual for detailed instructions.
  2. Connect the GE-41415-50  to the fuel fill pipe. Connect the J 41413-200  to the GE-41415-50  . Install the fuel tank filler cap to the GE-41415-50  .
    IMPORTANT: DO NOT exceed the specified value in this step. Exceeding the specified value may produce incorrect test results.
  3. Turn the nitrogen/smoke valve on theJ 41413-200  to nitrogen. Use the remote switch and attempt to pressurize the fuel tank with nitrogen to 5 in H20.
    • If the FTP sensor parameter indicates a pressure of 8.41 mmHg (4.5 in H20), test for a blockage or restriction in the EVAP vent line/hoses.
    • If no blockage or restrictions in the EVAP vent line/hoses are found, replace the EVAP vent solenoid.