FixVault

Installation Procedure

    Fig 1: Throttle Body
    GM1623767Courtesy of GENERAL MOTORS CORP.
  1. Install the throttle body.
  2. NOTE: Refer to Fastener Notice .
  3. Install the throttle body bolts.

    Tighten:  Tighten the bolts to 10 N.m (89 lb in).

  4. Fig 2: TAC Electrical Connector
    GM1623764Courtesy of GENERAL MOTORS CORP.
  5. Connect the TAC electrical connector (1).
  6. Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement .