Conditions for Running the DTC
- DTCs P0054, P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0117, P0118, P0120, P0121, P0122, P0123, P0128, P0141, P0201, P0202, P0203, P0204, P0205, P0206, P0207, P0208, P0220, P0442, P0443, P0446, P0449, P0455, P0496, P1258, P1516, P2101, P2135, P2176 are not set.
- The Engine Run Time parameter is more than 300 seconds.
- The Fuel Tank Level Remaining parameter is more than 10 percent.
- The Loop Status is closed.
- The Ignition 1 Signal parameter is between 10-18 volts.
- This diagnostic runs continuously when the above conditions are met.