FixVault

Circuit/System Testing

  1. If any other IPC indicators or gages are inoperative, refer to Symptoms - Instrument Panel, Gages and Console .
  2. Ignition OFF, disconnect the ECM harness connector.
  3. Ignition ON, connect a 3-amp fused jumper wire between the MIL control circuit and the negative terminal of the battery. The MIL should illuminate.
    • If the MIL does not illuminate, test the MIL control circuit for a short to voltage, short to ground, or an open/high resistance. If the circuit test normal, replace the IPC/bulb.