Scan Tool Data List
WARNING: This page is about a different car, the 2006 Chevrolet Corvette. However, it is still accessible from the selected car via links, so may be relevant.
Folding Top Control (FTC) Module
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ACCY or RUN, Vehicle in PARK, Folding Top Closed and Luggage Barrier In Place | |||
| 5 Bow Lowered Pos. Switch | Inputs | Active / Inactive | Inactive |
| 5 Bow Position CKT Status | Roof History Data | OK / Fault | OK |
| 5 Bow Raised Pos. Switch | Inputs | Active / Inactive | Inactive |
| 8-Digit GM Part Number | Module ID Information | Numeric | Varies |
| Battery Voltage Signal | Inputs | Volts | Varies |
| Calibration ID | Module ID Information | Numeric | Varies |
| Header Latch Switch | Inputs | Latched / Unlatched | Latched |
| Header Latch Switch | Roof History Data | Latched / Unlatched | Latched |
| Limit Switch Supply Voltage | Roof History Data | Present / Not Present | Present |
| Luggage Barrier In Place | Inputs | Yes / No | Yes |
| Luggage Barrier In Place | Roof History Data | Yes / No | Yes |
| Module Over Current Detected | Roof History Data | Yes / No | No |
| Module Over Voltage Detected | Roof History Data | No / Yes | No |
| Module Under Voltage Detected | Roof History Data | Yes / No | No |
| Motor Command | Outputs | amps | 0.00 amps |
| Motor X Direction Command | Outputs | On / Off | Off |
| Motor Y Direction Command | Outputs | On / Off | Off |
| Power Mode | Roof History Data | Accy. Or Run / Not Accy. Or Run | Accy. Or Run |
| Power Pull Down Ajar Status | Inputs | Closed / Ajar | Closed |
| Prom ID | Module ID Information | Numeric | Varies |
| Pull Down Position CKT Status | Roof History Data | OK / Fault | OK |
| Pump Motor Temp. Sensor | Outputs | °C / °F | Varies |
| Pump Over Temperature Sensor | Roof History Data | Normal / Overtemp | Normal |
| Tonneau Latch Switch | Inputs | Closed / Ajar | Closed |
| Tonneau Open Limit Switch | Inputs | Active / Inactive | Inactive |
| Tonneau Position CKT Status | Roof History Data | OK / Fault | OK |
| Too Cold For Top Operation | Roof History Data | Yes / No | No |
| Top Closed Limit Switch | Inputs | Active / Inactive | Inactive |
| Top Control Switch | Inputs | Inactive / Open / Close / Invalid | Inactive |
| Top Open Limit Switch | Inputs | Active / Inactive | Inactive |
| Trunk Ajar | Roof History Data | Closed / Ajar | Closed |
| Valve 1 Command | Outputs | On / Off | Off |
| Valve 2 Command | Outputs | On / Off | Off |
| Valve 3 Command | Outputs | On / Off | Off |
| Vehicle In Park | Roof History Data | Yes / No | Yes |
Body Control Module (BCM)
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ACCY or RUN, Vehicle in PARK, Folding Top Closed and Luggage Barrier In Place | |||
| Header Latch Switch | Keyless/Remote Start Data | Latched / Unlatched | Latched |
| Park Switch (Auto) | Keyless/Remote Start Data | Active / Inactive | Active |
| Tonneau Latch Sw. | Keyless/Remote Start Data | Closed / Ajar | Closed |
| Tonneau Pulldown Sw. | Keyless/Remote Start Data | Closed / Ajar | Closed |
| Tonneau Relay Cmd. | Keyless/Remote Start Data | Off / On | Off |
| Tonneau Release Switch | Keyless/Remote Start Data | Active / Inactive | Inactive |
| Trunk Ajar Switch | Keyless/Remote Start Data | Trunk Closed / Trunk Ajar | Trunk Closed |
Driver Door Module (DDM)
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ACCY or RUN, Vehicle in PARK, Folding Top Closed and Luggage Barrier In Place | |||
| 8-Digit GM Part Number | Data Display | Numeric | Varies |
| Window Normalization | Data Display | Yes / No | Yes |
Passenger Door Module (PDM)
| Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
|---|---|---|---|
| Operating Conditions: Ignition ACCY or RUN, Vehicle in PARK, Folding Top Closed and Luggage Barrier In Place | |||
| 8-Digit GM Part Number | Data Display | Numeric | Varies |
| Window Normalization | Data Display | Yes / No | Yes |