Installation Procedure
- Install a NEW throttle body gasket. Align the locating tab of the gasket with the notch in the manifold.
- Position the throttle body to the intake manifold.
- Install the throttle body bolts/nuts.
Tighten: Tighten the ECT sensor to 10 Nm (89 lb in).
- Position the heater inlet and outlet hose/pipe (2, 3).
- Position the heater inlet and outlet hose clamps at the engine pipes.
- Install the heater inlet and outlet pipe clip nuts (1) to the throttle body studs.
Tighten: Tighten the ECT sensor to 10 Nm (89 lb in).
- Connect the engine harness electrical connector (2) to the ETC.
- Install air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement .
- Fill engine cooling. Refer to DRAINING AND FILLING COOLING SYSTEM (STATIC FILL) .
- Install intake manifold cover. Refer to INTAKE MANIFOLD COVER REPLACEMENT .
- Connect a scan tool in order to test for proper throttle opening and throttle closing ranges.
- Operate the accelerator pedal and monitor the throttle angles. The accelerator pedal should operate freely, without binding, between closed throttle and wide open throttle (WOT).
- Verify that the vehicle meets the following conditions:
- The vehicle is not in a reduced engine power mode.
- The ignition is ON.
- The engine is OFF.
IMPORTANT:
Verify that the throttle actuator motor harness connector and the connector seal are properly installed and not damaged.