FixVault

Component Testing

  1. Measure for 70-110 ohms of resistance between terminals 85 and 86 of the EC ignition relay.
    • If the resistance is not within the specified range, replace the EC ignition relay.
  2. Measure for infinite resistance between the following terminals of the EC ignition relay:
    • 30 and 86
    • 30 and 87
    • 30 and 85
    • 85 and 87
    • If continuity is detected, replace the EC ignition relay.
  3. Connect a 20A fused jumper wire from B+ to relay terminal 85. Connect a jumper wire from ground to relay terminal 86. Measure for less than 2 ohms between terminals 30 and 87 of the relay.
    • If the resistance measures greater than 2 ohms, replace the EC ignition relay.