FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the VSS.
  2. Connect a test lamp between the ignition 1 voltage circuit of the VSS and ground.
  3. Ignition ON, verify that a test lamp illuminates between the ignition 1 voltage circuit and battery ground.
    • If the test lamp does not illuminate, test the ignition 1 voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition 1 voltage circuit fuse is open, test all components connected to the ignition 1 voltage circuit and replace as necessary.
  4. Ignition OFF, test for less than 5.0 ohms of resistance between the ground circuit and ground.
    • If greater than 5.0 ohms repair the ground circuit for an open/high resistance.
  5. Ignition ON, test for 9-11 volts between the signal circuit of the VSS and ground.
    • If less than 9 volts test the VSS signal circuit for a short to ground or an open/high resistance. If the circuit/connections test normal, replace the ECM.
    • If greater than 11 volts test the VSS signal circuit for a short to voltage. If the circuit/connections test normal, replace the ECM.
  6. If the voltage is within the specified range replace the VSS.