FixVault

Circuit/System Testing

    IMPORTANT: If the CKP sensor lead is damaged in any way, replace the CKP sensor.
  1. Ignition OFF, disconnect the harness connector at the CKP sensor.
  2. Ignition ON, test for 2-3 volts between the signal circuit terminal 1 and the low reference circuit terminal 2.
    • If less than the specified range, test the applicable circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
    • If greater than the specified range, test the applicable circuit for a short to voltage. If the circuit tests normal, replace the ECM.
  3. If all circuits test normal, test or replace the CKP sensor.