FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connectors at the appropriate module.
  2. Ignition OFF and scan tool disconnected, open and close the driver door, and wait 1 minute. Test for less than 5 ohms between the appropriate ground circuit terminals listed below and ground.
    • Terminal 1 (IPC)
    • Terminal 9 (DRR)
    • Terminal 17 X1 (BCM)
    • Terminal 19 X1 (BCM)
    • Terminal 20 X1 (BCM)
    • Terminal 50 X2 (BCM)
    • Terminal A X1 (HVAC)
    • Terminal A12 X1 (Radio)
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Verify that a test lamp illuminates between the appropriate B+ circuit terminals listed below and ground.
    • Terminal 12 (IPC)
    • Terminal 16 (DRR)
    • Terminal 46 X1 (BCM)
    • Terminal 50 X1 (BCM)
    • Terminal 51 X1 (BCM)
    • Terminal 52 X1 (BCM)
    • Terminal 49 X2 (BCM)
    • Terminal D X1 (HVAC)
    • Terminal B1 X1 (Radio)
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  4. If all circuits test normal, replace the appropriate module.