Circuit/System Testing

  1. Verify that DTC P0562 is not set.
  2. Ignition OFF, disconnect the harness connector of the K27 fuel pump control module.
  3. Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 21 and ground.
    • If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.