FixVault

Removal Procedure

    Fig 1: Fuel Level Sensor And Retainer
    GM1940129Courtesy of GENERAL MOTORS CORP.
  1. Remove the fuel tank fuel pump module. Refer to Fuel Tank Fuel Pump Module Replacement .
  2. Disconnect the fuel level sensor wiring pigtail electrical connector from the module cover.
  3. Gently lift up the fuel level sensor retainer (1), disengaging the retainer from the sensor.
  4. Slide the fuel level sensor (2) down from the reservoir.