FixVault

Installation Procedure

  1. Fig 1: Turbocharger Vane Position Sensor
    GM1731868Courtesy of GENERAL MOTORS CORP.
    CAUTION:

    Refer to Fastener Caution .


    Install the turbocharger vane position sensor to the turbocharger and tighten to 28 N.m (21 lb ft) .
  2. Install the turbocharger vane position sensor connector to the bracket located on the LH valve cover.
  3. Fig 2: Turbocharger Vane Position Sensor Wiring Harness Electrical Connector
    GM1731857Courtesy of GENERAL MOTORS CORP.
  4. Connect the turbocharger vane position sensor electrical connector.
  5. Perform the turbocharger learn procedure. Refer to Turbocharger Learn .