FixVault

Installation Procedure

    Fig 1: Diesel Fuel Conditioning Module Lower Assembly
    GM1665456Courtesy of GENERAL MOTORS CORP.
    NOTE:

    The water-in-fuel sensor must ONLY be tightened by hand.

  1. Install the diesel strainer bowl assembly.
  2. Connect the electrical connector.
  3. Prime the fuel system. Refer to Fuel System Priming .
  4. Start the engine. If the engine stalls, repeat the above step.
  5. Once the engine starts, inspect for fuel leaks.