FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the X1 harness connector at the K20 ECM.
  2. Ignition ON, the MIL should not illuminate.
    • If the MIL is illuminated, test the MIL control circuit terminal 46 X1 for a short to ground. If the circuit tests normal, replace the P16 instrument panel cluster.
  3. Connect a 3 A fused jumper wire between the MIL control circuit terminal 46 X1 and ground. The MIL should illuminate.
    • If the MIL illuminates, replace the K20 ECM.
    • If the MIL does not illuminate, test the MIL control circuit terminal 46 X1 for a short to voltage or an open/high resistance. If the MIL control circuit tests normal, test the instrument panel cluster ignition voltage circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the P16 instrument panel cluster/bulb.