FixVault

Battery Positive and Negative Cable Replacement (APM Module Ground Cable)

Fig 1: Locating Battery Positive and Negative Cables
GM2359321Courtesy of GENERAL MOTORS CORP.
Callout Component Name

Preliminary Procedures

  1. Disable the high voltage. Refer to High Voltage Disabling
  2. Remove the rear compartment floor stowage trim compartment. Refer to Rear Compartment Floor Stowage Trim Compartment Replacement
  3. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .
1 Accessory DC Power Control Module Nut
CAUTION: Refer to Fastener Caution .

Tighten:  22 N.m (16 lb ft)

2 Accessory DC Power Control Module Bracket Nut

Tighten:  22 N.m (16 lb ft)

3 Battery Negative Cable