FixVault

Dynamic Test

  1. Remove the appropriate Q6 camshaft position actuator solenoid valve.
  2. Install a 10 A fused jumper wire between the control circuit terminal 2 and 12 V. Momentarily install a jumper wire between the low reference terminal 1 and ground. The pintle should extend.
    NOTE:
    • The camshaft position actuator solenoid pintle should be facing downward for this test.
    • Do not allow electrical current to flow through the camshaft position actuator solenoid for greater than 1-2 s.
    • If the function does not perform as specified, replace the Q6 camshaft position actuator solenoid valve.