Refrigerant System Specifications
| Application | Specification | |
|---|---|---|
| Metric | English | |
| POE Oil GM P/N 88862657 for United States POE Oil GM P/N 88862658 for Canada |
||
| Refrigerant Charge, R134a | 950 g | 2.1 lb |
| Total System PAG Oil Capacity | 180 ml | 6.1 oz. |
| Compressor2 | 100 ml1 | 3.4 oz.1 |
| Condenser | 20 ml1 | 0.7 oz.1 |
| Desiccant Cartridge | 10 ml1 | 0.3 oz.1 |
| Evaporator | 10 ml1 | 0.3 oz.1 |
| Drive Motor Battery Cooler | 10 ml1 | 0.3 oz.1 |
| Abrupt Refrigerant Loss | 60 ml3 | 2.0 oz.3 |
| 1
If more than the specified amount of POE oil was drained from a component, add the equal amount of oil drained. 2 The service compressor contains 100 ml (3.4 oz.) of POE oil. 3 Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component. |
||