FixVault

Circuit/System Verification

  1. Ignition ON
  2. Verify the Instrument Cluster Traction Control indicator turns ON and OFF when commanding the Instrument Cluster All Indicators ON and OFF with a scan tool.
    • If the indicator does not turn ON and OFF 

      Replace the P16 Instrument Cluster.

    • If the indicator turns ON and OFF 
  3. Verify the scan tool electronic brake control module Traction Control Switch parameter changes between Active and Inactive while pressing and releasing the S48E Multifunction Switch-Center Console.
    • If the parameter changes 
  4. All OK.