Circuit/System Verification

WARNING: This page is about a different car, the 2010 Cadillac SRX. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Check for bulletins before proceeding.
  1. Ignition ON, place the blower motor switch in each speed position. Verify that the blower motor operates properly in each position.
    • If the blower motor does not operate properly in all speeds, refer to DTC B0193 .
  2. Ignition ON, place the auxiliary blower motor switch in each speed position. Verify that the auxiliary blower motor operates properly in each position.
    • If the auxiliary blower motor does not operate properly in all speeds, refer to DTC B0208 .
  3. Using the scan tool observe the mode, temperature, air inlet and recirculation door positions. Verify the actual and commanded door positions are within 4 counts of each other.
  4. Engine ON, A/C ON, place the temperature control in the coldest position. Verify that cool air flows from the ducts in the vehicle.
  5. Turn the A/C OFF and place the temperature control in the warmest position.
  6. Engine OFF, ignition ON, cover the sunload sensor assembly with a shop towel or other suitable item. Verify the scan tool Sunload Sensor parameter changes.
  7. Measure actual inside air temperature using a thermometer. Compare this value to the scan tool Inside Passenger Compartment Air Temp. Sensor parameter. The measured temperature should be within 5 degrees of parameter.
  8. Measure actual temperature using a thermometer at each of the duct temperature sensors. Compare this value to the appropriate scan tool Duct parameter. The measured temperature should be within 5 degrees of appropriate Duct Temperature Sensor parameter.
  9. Ignition ON, observe the scan tool A/C Evaporator Temperature Sensor parameter. The reading should be between -39°F (-35°C) and 185°F (85°C) and change with evaporator air temperature changes.