FixVault

Battery Positive and Negative Cable Replacement (APM Module Ground Cable)

WARNING: This page is about a different car, the 2011 Chevrolet Volt. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Locating Battery Positive and Negative Cables
GM2359321Courtesy of GENERAL MOTORS CORP.
Callout Component Name

Preliminary Procedures

  1. Disable the high voltage. Refer to High Voltage Disabling
  2. Remove the rear compartment floor stowage trim compartment. Refer to Rear Compartment Floor Stowage Trim Compartment Replacement
  3. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .
1 Accessory DC Power Control Module Nut
CAUTION: Refer to Fastener Caution .

Tighten:  22 N.m (16 lb ft)

2 Accessory DC Power Control Module Bracket Nut

Tighten:  22 N.m (16 lb ft)

3 Battery Negative Cable