FixVault

Circuit/System Testing

  1. Vehicle OFF, remove the F103 drive motor generator control module sight shield. Refer to Drive Motor Generator Power Inverter Module Cover Replacement .
  2. Disconnect the T6 power inverter module X1 connector and the ECM X1 connector.
  3. Test for less than 1 Ω between the serial data circuits listed below:
    • T6 power inverter module X1 connector terminal 10 and K20 ECM X1 connector terminal 43
    • T6 power inverter module X1 connector terminal 11 and K20 ECM X1 connector terminal 29
    • If greater than the specified range, test the serial data circuit for an open/high resistance condition. If the circuit tests normal, replace the K20 ECM.
  4. If the DTC is set, program the T6 power inverter module. If the DTC resets, replace the T6 power inverter module.