FixVault

Circuit/System Verification

  1. Ignition ON
  2. Verify the Instrument Cluster Traction Control indicator listed below turns On and Off when commanding the Instrument Cluster All Indicators On and Off with a scan tool.
    • Traction control off indicator
    • Stability control off indicator
    • Traction/stability control indicator
    • If the indicator does not turn On and Off 

      Replace the P16 Instrument Cluster.

    • If the indicator turns ON and OFF 
  3. Verify the scan tool Traction Control Switch parameter changes between Active and Inactive while pressing and releasing the S75 Traction Control Switch.
    • If the parameter changes 
  4. All OK.