FixVault

Circuit/System Testing

  1. Vehicle ON.
  2. Verify that no K1 14V Power Module or B18 Battery Current Sensor DTCs are set that would cause a charging system concern.
    • If no applicable DTCs are set 
  3. Vehicle OFF.
  4. Test for 12.4 V or greater at room temperature across the C1 Battery terminals.
    • If within the specified range 
  5. Connect a carbon pile tester to the C1 Battery.
  6. Vehicle ON, turn all accessories off. Observe the voltage reading on the tester. The voltage should read between 12.6-15.5V.
  7. Adjust the carbon pile tester so that the 12V Current on the 14V Power Module data list is reading 160 amps.
  8. Verify the voltage reading remains between 12.6-15.5V.
    • If not within the specified range 

      Replace the K1 14V Power Module.

    • If within the specified range 
  9. All OK