Installation Procedure

  1. Install the exhaust pressure sensor (2).
    Fig 1: Exhaust Pressure Sensor
    GM2966398Courtesy of GENERAL MOTORS COMPANY
  2. Connect the wiring harness plug to exhaust pressure sensor (2).
  3. Install the 2 hoses (3) to the exhaust pressure sensor (2).
  4. Install the 2 clamps (4).
  5. Install the exhaust pressure sensor nut (1) and tighten to 8 N.m (70 lb in).
    CAUTION: Refer to Fastener Caution .
  6. Install the engine sight shield. Refer to Engine Sight Shield Replacement .
  7. Connect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection .