Removal Procedure

  1. Disconnect mass air flow sensor wiring harness plug (2) from mass air flow sensor (3).
    Fig 1: Air Cleaner Housing, Mass Air Flow Sensor Wiring Harness Plug And Mass Air Flow Sensor
    GM2191533Courtesy of GENERAL MOTORS COMPANY
  2. Unclip mass air flow sensor wiring harness retainer clip from air cleaner housing (1).
  3. Remove the air cleaner outlet duct clamp (3).
    Fig 2: Air Cleaner Housing Air Cleaner Housing, Mass Air Flow Sensor Wiring Harness Plug And Mass Air Flow Sensor
    GM2191547Courtesy of GENERAL MOTORS COMPANY
  4. Remove the air cleaner outlet duct (2) from air cleaner housing (1).
  5. Remove the 5 air cleaner housing bolts (1).
    Fig 3: Air Cleaner Element
    GM2191545Courtesy of GENERAL MOTORS COMPANY
  6. Remove the air cleaner upper housing (2) from the air cleaner lower housing (4).
  7. Remove the air cleaner element (3).