FixVault

Battery Negative Cable Disconnection and Connection

Fig 1: Battery Negative Cable Disconnection and Connection
GM2917976Courtesy of GENERAL MOTORS COMPANY
Callout Component Name

Preliminary Procedures

  1. Turn the ignition OFF.
  2. Record radio and engine oil life resets.
  3. Disconnect and remove all 12V battery chargers and the AC charger cable from the hybrid battery charger receptacle.
1 Battery Negative Cable Fastener
WARNING:

Refer to Battery Disconnect Warning

CAUTION:

Refer to Fastener Caution .


Tighten 
5 N.m (44 lb in)
2 Battery Negative Cable