FixVault

Installation Procedure

  1. GM4163118Courtesy of GENERAL MOTORS COMPANY

    Battery Energy Control Module (2) - Install

  2. Fig 1: Identifying Battery Energy Control Module Connectors With Reconnect Sequence (1 Of 2)
    GM4163116Courtesy of GENERAL MOTORS COMPANY
    CAUTION:

    The battery energy control modules internal cell balancing circuitry is powered by the cell group voltage sense circuits. In order to prevent an unrecoverable, unbalanced Hybrid/EV battery section or internal control module damage, always take the following actions:

    1. Disconnect ALL of the battery energy control module connectors prior to disconnecting any Hybrid/EV battery section connector.
    2. Reconnect all the Hybrid/EV battery section connectors prior to reconnecting the battery energy control module connectors.
    3. Disconnect and reconnect the battery energy control module connectors ONLY in the sequence provided in Repair Instructions.

    Connect the battery energy control module connectors in the sequence shown above.

  3. Fig 2: Identifying Battery Energy Control Module Connectors With Reconnect Sequence (2 Of 2)
    GM4163108Courtesy of GENERAL MOTORS COMPANY

    Connect the battery energy control module connectors in the sequence shown above.

  4. High Voltage Battery Cover Replacement  - Install
  5. Drive Motor Battery Replacement and Shipping Preparation  - Install
  6. NOTE:

    Service replacement module requires programming.

  7. Program the battery energy control module. Control Module References