Removal Procedure
- Safety glasses with appropriate side shields when within 50 feet of the vehicle, either indoors or outdoors
- Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors
- Visually and functionally inspect the gloves before use.
- Wear the Insulation gloves at all times when working with the high voltage battery assembly, whether the system is energized or not.
- High Voltage Battery Cover Replacement - Remove
- High Voltage Battery Disconnect Relay Replacement - Remove
Terminal Cover (1) - Open
- Fastener (2) - Remove
- Battery Current Sensor Connector (3) - Disconnect
Fastener (1) - Remove [2x]
Battery Current Sensor (1) - Remove
WARNING:
Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:
Failure to follow the procedure exactly as written may result in serious injury or death.