Circuit/System Description
The hybrid powertrain control module 2 monitors the voltage values of the fuel fill door open request wake-up signal circuit and the fuel door request signal circuit. When the refuel request switch is pressed, the two switch contacts close. This provides B+ to the Wake-up Circuit input of the hybrid powertrain control module 2 and lowers the voltage on the fuel door request signal circuit input to the hybrid powertrain control module 2.
The hybrid powertrain control module 2 detects the voltage on the signal circuits and commands the fuel system to vent and sends a serial data message to the driver information center to display the Wait to Refuel message. The hybrid powertrain control module 2 then energizes the fuel door lock/unlock actuator to unlock the fuel door