FixVault

Component Testing

  1. Vehicle OFF and all vehicle systems OFF. Disconnect the X2 harness connector at the X98 Hybrid/EV Battery Charger Receptacle.
  2. Test for 2.76 - 2.93k Ω at approximately 25°C (77°F) between the signal terminal 5 and the low reference terminal 6.
    • If not within the specified range 

      Replace the X98 Hybrid/EV Battery Charger Receptacle.

    • Go to next step: If within the specified range 
  3. All OK.