FixVault

Installation Procedure

  1. GM4529674Courtesy of GENERAL MOTORS COMPANY

    Drive Motor Power Inverter Module 3-Phase Cable (1) - Install

  2. GM4529673Courtesy of GENERAL MOTORS COMPANY
    CAUTION:

    Refer to Fastener Caution .

    Drive Motor Power Inverter Module 3-Phase Cable Bolt (4) - Tighten [ 3x ] 9 N.m (80 lb/in)

  3. Drive Motor Power Inverter Module 3-Phase Cable Connector Cover Seal (3) - Install NEW
  4. Drive Motor Power Inverter Module 3-Phase Cable Connector Cover (2) - Install
  5. Drive Motor Power Inverter Module 3-Phase Cable Connector Cover Bolt (1) - Install [ 2x ] 9 N.m (80 lb/in)
  6. Drive Motor Rear Mount Bracket - Install - Drive Motor Rear Mount Bracket Replacement
  7. Enable the high voltage system. High Voltage Enabling