X51A Fuse Block - Instrument Panel
| - |
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
|---|---|---|---|
| I | 13575832 | J-35616-4A (PU) | J-38125-11A |
| II | 13575835 | J-35616-43 (RD) | J-38125-11A |
| III | 13575850 | J-35616-14 (GN) | J-38125-557 |
| IV | 13578908 | J-35616-5 (PU) | J-38125-11A |
| V | 19354836 | J-35616-43 (RD) | J-38125-11A |
| VI | 19368264 | J-35616-35 (VT) | J-38125-11A |
| VII | 19368264 | J-35616-4A (PU) | J-38125-11A |
| VIII | 19368264 | J-35616-64B (LT BU) | J-38125-11A |
| IX | Not required | J-35616-22 (RD) | No Tool Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 16 | 2.5 | RD / GY | 3540 | Battery Positive Voltage | VII | C3U |
| 18 | 2.5 | RD / GY | 1342 | Battery Positive Voltage | VII | KA1/KU9 |
| 19 | 0.5 | RD / GN | 3840 | Battery Positive Voltage | VI | - |
| 20 | 2 | RD / YE | 5040 | Battery Positive Voltage | IV | - |
| 21 | 2.5 | BN / BK | 4629 | DC/AC Inverter Control | IV | KI6/KI7 |
| 22 | 2 | RD / BN | 1440 | Battery Positive Voltage | IV | - |
| 26 | 3 | RD / BU | 42 | Battery Positive Voltage | II | - |
| 27 | 0.35 | RD / WH | 5440 | Battery Positive Voltage | II | - |
| 28 | 10 | RD / BU | 42 | Battery Positive Voltage | IX | - |
| 29 | 4 | RD / VT | 542 | Battery Positive Voltage | V | - |
| 30 | 10 | RD / VT | 842 | Battery Positive Voltage | IX | - |
| 31 | 2.5 | RD / YE | 3740 | Battery Positive Voltage | VII | - |
| 33 | 0.5 | RD / GN | 4440 | Battery Positive Voltage | VI | - |
| 34 | 2.5 | RD / YE | 1442 | Battery Positive Voltage | VII | KA1/KU9 |
| 35 | 0.5 | RD / BN | 1140 | Battery Positive Voltage | VI | - |
| 36 | 1 | RD / GY | 2140 | Battery Positive Voltage | VIII | - |
| 37 | 0.5 | RD / VT | 3340 | Battery Positive Voltage | VI | - |
| 38 | 2.5 | RD / GN | 1840 | Battery Positive Voltage | VII | C3U |
| 39 | 0.35 | RD / WH | 140 | Battery Positive Voltage | VI | - |
| 40 | 0.35 | RD / GY | 4140 | Battery Positive Voltage | VI | N06 |
| 41 | 0.35 | RD / WH | 140 | Battery Positive Voltage | VI | - |
| 42 | 1 | RD / WH | 3440 | Battery Positive Voltage | VIII | - |
| 43 | 3 | RD / BU | 42 | Battery Positive Voltage | IV | - |
| 44 | 1 | RD / BN | 3640 | Battery Positive Voltage | IV | N38 |
| 45 | 2 | RD / VT | 4040 | Battery Positive Voltage | IV | - |
| 1A | 2.5 | RD / GN | 40 | Battery Positive Voltage | VII | - |
| 1B | 0.75 | RD / VT | 340 | Battery Positive Voltage | VIII | - |
| 10A | 2.5 | RD / GN | 40 | Battery Positive Voltage | VII | - |
| 10B | 0.35 | RD / VT | 1640 | Battery Positive Voltage | VI | - |
| 11A | 1 | RD / BU | 2540 | Battery Positive Voltage | VIII | - |
| 11B | 3 | RD / BU | 42 | Battery Positive Voltage | I | - |
| 12A | 2 | VT | 1701 | Retained Accessory Power Control | VII | K4C |
| 12B | 0.75 | VT | 4601 | Retained Accessory Power Control | VIII | K4C |
| 13A | 0.75 | RD / WH | 2740 | Battery Positive Voltage | VIII | - |
| 13B | 2.5 | RD / YE | 2172 | 12V Regulated Supply Voltage 1 | VII | - |
| 14A | 2.5 | RD / GN | 40 | Battery Positive Voltage | VII | - |
| 14B | 0.35 | RD / GY | 2840 | Battery Positive Voltage | VI | - |
| 15A | 0.75 | VT | 2101 | Retained Accessory Power Control | VIII | - |
| 15B | 2 | VT | 1701 | Retained Accessory Power Control | VII | K4C |
| 2A | 2.5 | RD / GN | 40 | Battery Positive Voltage | VII | - |
| 2B | 0.35 | RD / BU | 3240 | Battery Positive Voltage | VI | - |
| 23A | 2 | VT | 1701 | Retained Accessory Power Control | VII | K4C |
| 23AA | 0.35 | BK | 1650 | Ground | III | - |
| 23D | 0.35 | GY / VT | 755 | Retained Accessory Power Relay Coil Control | III | - |
| 23E | 2.5 1.5 |
VT VT |
801 801 |
Retained Accessory Power Control Retained Accessory Power Control |
VII VII |
1NA -1NA |
| 23F | 2.5 | RD / GN | 1840 | Battery Positive Voltage | VII | C3U |
| 23G | 3 | RD / YE | 2172 | 12V Regulated Supply Voltage 1 | I | - |
| 23H | 0.35 | VT / BU | 3263 | Logistics Mode Relay Open Control | III | - |
| 23J | 0.35 | GY / VT | 3264 | Logistics Mode Relay Close Control | III | - |
| 23K | 2.5 | RD / GN | 40 | Battery Positive Voltage | VII | - |
| 23L | 0.35 | GY / GN | 4083 | Retained Accessory Power Relay 2 Coil Control | III | - |
| 23N | 2 | RD / BU | 42 | Battery Positive Voltage | VII | - |
| 23R | 0.35 | GY / GN | 4083 | Retained Accessory Power Relay 2 Coil Control | III | - |
| 23U | 2 | RD / BU | 42 | Battery Positive Voltage | II | - |
| 23W | 2 | VT | 1701 | Retained Accessory Power Control | II | - |
| 3A | 0.5 | RD / GN | 2173 | 12V Regulated Supply Voltage 2 | VI | UV2 |
| 3B | 2.5 | RD / GN | 2173 | 12V Regulated Supply Voltage 2 | VII | UV2 |
| 4A | 2.5 | RD / GN | 40 | Battery Positive Voltage | VII | (UE1/UER) |
| 4B | 0.5 | RD / YE | 740 | Battery Positive Voltage | VI | (UE1/UER) |
| 5A | 0.35 | RD / GN | 3140 | Battery Positive Voltage | VI | UD7 |
| 5B | 2.5 | RD / GN | 2173 | 12V Regulated Supply Voltage 2 | VII | UD7 |
| 6A | 2.5 | VT | 801 | Retained Accessory Power Control | VII | - |
| 6B | 0.35 | VT | 2901 | Retained Accessory Power Control | VI | - |
| 8A | 1.5 | VT | 1001 | Retained Accessory Power Ignition Voltage | II | - |
| 8B | 2 | VT | 1701 | Retained Accessory Power Control | II | - |
| 9A | 2.5 | RD / GN | 2173 | 12V Regulated Supply Voltage 2 | VII | - |
| 9B | 1 | RD / BN | 2240 | Battery Positive Voltage | VIII | - |