Removal Procedure
- Disable the high voltage system. High Voltage Disabling
Drive Motor Battery Charger Receptacle Bolt (1) - Remove [2x]
- Retainer (2) - Remove
- High Voltage Electrical Connector (3) - Disconnect [2x] - High Voltage Connectors
Retainer (1) - Remove
- High Voltage Electrical Connector (2) - Disconnect - High Voltage Connectors
Generator Bolt (1) - Remove [2x]
- Battery Charger Coupler Fuse Block (2) - Remove
NOTE:
Disconnecting high voltage electrical connectors and testing for voltage MUST be performed during the high voltage disabling procedure but, for graphic clarity, the connector(s) are shown still connected.
NOTE:
Disconnecting high voltage electrical connectors and testing for voltage MUST be performed during the high voltage disabling procedure but, for graphic clarity, the connector(s) are shown still connected.