FixVault

Removal Procedure

  1. Disable the high voltage system. High Voltage Disabling
  2. GM6727327Courtesy of GENERAL MOTORS COMPANY

    Drive Motor Battery Charger Receptacle Bolt (1) - Remove [2x]

  3. Retainer (2) - Remove
  4. NOTE:

    Disconnecting high voltage electrical connectors and testing for voltage MUST be performed during the high voltage disabling procedure but, for graphic clarity, the connector(s) are shown still connected.

  5. High Voltage Electrical Connector (3) - Disconnect [2x] - High Voltage Connectors
  6. GM6727329Courtesy of GENERAL MOTORS COMPANY

    Retainer (1) - Remove

  7. NOTE:

    Disconnecting high voltage electrical connectors and testing for voltage MUST be performed during the high voltage disabling procedure but, for graphic clarity, the connector(s) are shown still connected.

  8. High Voltage Electrical Connector (2) - Disconnect - High Voltage Connectors
  9. GM6727331Courtesy of GENERAL MOTORS COMPANY

    Generator Bolt (1) - Remove [2x]

  10. Battery Charger Coupler Fuse Block (2) - Remove