FixVault

Air Pump Test

  1. Disconnect vacuum line and connect external vacuum source to air pump and operate at 15-20 inches.
  2. Feel air pump to see if it is operating, (pump pulsates during pumping cycle).
  3. If pump is operating, disconnect outlet air line and stop line with finger.
  4. If pump continues to operate with outlet stopped, the pump is leaking internally and must be replaced.
  5. If pump fails to operate, disconnect air line at outlet side to eliminate possibility of back pressure.
  6. If pump does not operate with line disconnected, check for vacuum at inlet fitting.
  7. If vacuum is good, pump must be replaced.