Float Level

  1. Remove air horn and gasket. Turn air horn upside down. Allow weight of float to press down against float needle valve. See Fig 1 .
    Fig 1: Float Level Adjustment Bend tang to adjust.
    G456
  2. Measure float level specified clearance between top of float and air horn gasket surface. Clearance can be checked using a specified drill or pin gauge.
  3. Make sure float tang still rests on float needle when clearance is checked. To adjust, bend tang that contacts float needle.
NOTE: DO NOT  apply pressure to float needle while checking or changing adjustment.