BOSCH, MITSUBISHI & NIPPONDENSO STARTER SPECIFICATIONS

Application Specification
Direct Drive Starter
Cranking Amperage Draw 120-160 Amps
No Load Test Voltage 11 Volts
No Load Test Amperage Draw 47 Amps
No Load Minimum RPM 6600
Reduction Gear Starter
Cranking Amperage Draw 150-210 Amps
No Load Test Voltage 11 Volts
No Load Test Amperage Draw 85 Amps
No Load Test Minimum RPM 3700
Solenoid Closing Voltage (All) 7.5 Volts