  1. Remove switch from front harness. Connect a jumper lead between Red wire terminal in center section of connector and either Red/Green or Yellow/Green connection in front section. Connect another jumper between Black terminal in center section and open connection in front section.
  2. If motor does not operate, reverse jumper connections in front section. If motor still does not operate, either harness or complete 3-motor assembly may be defective.
Fig 1: Master Switch Connector Test Points E Class, New Yorker and 600 shown.
G908