FixVault

Test 7D - Short To Battery

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATION  . For appropriate wiring diagram, see WIRING DIAGRAMS  at end of article.

Using DRB-II in ohmmeter mode, check OTIS connector system ground circuit (Black/Light Green wire). If resistance is more than 5 ohms, repair open circuit in Black/Light Green wire. Perform VERIFICATION PROCEDURE VER-1. If resistance is less than 5 ohms, replace OTIS. Perform VERIFICATION PROCEDURE VER-1.