Test 24A - Electronic Instrument Cluster (EIC) Switch Test
- Using DRB-II, read Electronic Instrument Cluster (EIC) trip reset switch status. If DRB-II displays CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1. If DRB-II does not display CIRCUIT CLOSED, press TRIP RESET button on electronic instrument cluster.
- If DRB-II does not display CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1. If DRB-II displays CIRCUIT CLOSED, read electronic instrument cluster trip switch status using DRB-II.
- If DRB-II displays CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1. If DRB-II does not display CIRCUIT CLOSED, press TRIP button on electronic instrument cluster. If DRB-II does not display CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1.
- If DRB-II displays CIRCUIT CLOSED, read electronic instrument cluster US/metric switch status using DRB-II. If DRB-II displays CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1. If DRB-II does not display CIRCUIT CLOSED, press US/METRIC button on electronic instrument cluster.
- If DRB-II does not display CIRCUIT CLOSED, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1. If DRB-II displays CIRCUIT CLOSED, instrument cluster switches are operational. Retest system. Perform VERIFICATION PROCEDURE VER-1.